Specifications
8
2-5
Terminal Block
The terminal blocks in the rear of the product are for the connection of PTZ / Sensor / Relay / POS Connection.
The number of the terminal block may be different depending on the model.
① PTZ Camera/Keyboard Controller
Connect PTZ control cable; TRX+, TRX- and GND to Terminal Block(TB1);No.4 TRXD+, No.5 TRXD- and No.10
GND in the rear of NVR. You may refer to APPENDIX for supported PTZ cameras in this manual. Keyboard
controller has the same connection as PTZ camera.
② Sensor / Relay / POS
Connect Sensor / Relay / POS to the terminal block directly depending on the model.
Sensor and Relay Type
NC(Normal Close) : Normally closed; opens when a signal is received
NO(Normal Open) : Normally open; closes when a signal is received
The external alarm device may require the power supply depending on its type.
Be cautious.
Chapter 3. Operation and Setup Tools and HDD Install
NVR Model can be controlled easily by using the front panel, remote controller and mouse.
3-1
Remote Controller
POWER
Turn the system power
ON or OFF.
MODE
FULL 1CH Mode
QUAD 4CH Mode
9 SPLIT 9CH Mode
16 SPLIT 16CH Mode
SEQ. Sequence Mode ON/OFF
B) System Operation and Setup Button
MENU Data, Schedule, System Set up