User's Manual
Tele
Eye
RX
User
Guide Page 25
Setup
Tele
Eye RX for LAN Connection with Static IP
Step 11a: Configure
Tele
Eye RX transmitter IP setting through CCTV Monitor
RG59 cable
Power Adapter
Ethernet
Socket
Tele
Eye RX
Cameras
CCTV
Monitor
RG59 cable
192.168.0.2
Press the “Menu” button such that the OSD
main menu
opens on the monitor.
Use “Up” or “Down” button to select
[SETUP] option and press “Enter”
button
to enter [SETUP] sub menu.
Select [CONNECTION] option and press
“Enter”
button to enter connection setting
menu.
Select [TCP/IP] option and Press “Enter”
button
Select [IP] option and press “Enter” button.
IP address consists of four fields. Each field can
assign a number from 0 to 255
SETUP MENU
VIDEO . . .
RECORDING . . .
SWITCHES . . .
DATE / TIME . . .
CONNECTION . . .
EVENT HANDLER . . .
TRANSMITTER . . .
RESTORE FACTORY SETTING ENTER
CONNECTION
TCP / IP …
MODEM …
TCP / IP
IP 192.168.0.2
PORT 1024
SUBNET MASK 255.255.255.0
ENABLE GATEWAY NO
GATEWAY 0.0.0.0
ENABLE DNS NO
PRIMARY DNS 0.0.0.0
SECONDARY DNS 0.0.0.0
SURELINK …