User's Manual
Tele
Eye
RX
User
Guide Page 132
Event Action
II. Switch
Switch allows transmitter to control 4 external relays which are defined by user.
Switch Type
Switch has 2 types. They are latching or push-button type. In latching type, the switch turns
on for a period of time. In push-button type, the switch turns on and off after 1 second.
Latching Duration
The latch duration period is the time for turning on the switch.
Action Delay
The delay is the period of time after turning off the switch before next turning on.
Latching Duration and Action Delay Example
For latch type switch, set latch duration 10sec and
action delay 10sec. If an event trigger, the timing of the
switch is shown on the right.
For push-button type switch, set latch duration 10sec and action
delay 10sec. If an event trigger, the timing of the switch is shown
on the right.
Switch Action setup procedure
Step 1: In the action menu, select [SWITCH]
option and press “Enter”
button to
enter the switch action setting menu.
XXXXXXX ACTION
RECORDING …
SWITCH …
DIALBACK …
BUZZER …
EVENT LED …
LIVE CAMERA …
PTZ …