User's Manual

Tele
Eye
RX
User
Guide Page 112
Event Handling
Example of Entry/Exit Zone WITH Security Switch Usage
For Entry Zone :
The entry delay is the period of time between entering the surveillance zone and reaching the
transmitter. In order to disarm the system for maintenance or repair, user / installer needs to turn
off the security switch and enter the surveillance zone. However, the delay time starts from the
1
st
trigger by the 1
st
alarm sensor (i.e. Alarm 4). Note that if user enables recording action,
recording action is automatically activated during entry delay.
The detail procedure is as below:
1) user turns off security switch
2) the alarm is at entry delay
3) the 1
st
trigger is made by Alarm 4 (i.e. user enter the surveillance zone and the entry delay
time begin)
4) 2
nd
, 3
rd
and 4
th
trigger are made and each entry delay starts respectively
5) user disarms the system for maintenance
For example: If the time for going from security switch to transmitter is about 8 minutes, Delay
1 should be longer than 8 minutes, while Delay 2 should be longer than the time for going from
security switch to Alarm 2, and so on.
Alarm 4Alarm 3Alarm 2Alarm 1
Entry
Security Switch
Surveillance zone
Delay4Delay3Delay2Delay1
Time line
Tel
e
Eye RX
DISARM