Guide Page 111
Event Handling
III. Alarm
Alarm
It is an input to the transmitter from external alarm sensors
.
Alarm can be used to detect many
events occur at the surveillance area, such as fire and illegal entering by someone. The alarm
event supports BS 8418:2003 which has arm/disarm and security switch function.
Sensor Tamper Type
Alarm tamper event triggers if someone cuts the wire between the alarm input and the
transmitter. This event behaves as fire zone type that can be triggered once the wire being cut.
Alarm tamper type has choice of none, SEOL, DEOL. (Please refers to P.100 Tamper Circuit
Section of User Guide)
Sensor Type
The alarm sensor input circuit type is normal close (NC). The state of the circuit is close, it
indicates normal of
Tele
Eye RX. Otherwise, the state of the circuit is open, it indicates alarm
trigger of
Tele
Eye RX. The alarm sensor input circuit type is normal open (NO). The state of
the circuit is
open
, it indicates
normal
of
Tele
Eye
RX
. Otherwise, the state of the circuit is
close, it indicates alarm trigger of
Tele