Event Handling
I. Arm/Disarm
Arm/Disarm
Arm/Disarm input is used for enhancing security level of the surveillance area. This input
introduce the concept of 3 zone types for alarm, fire zone, normal and entry exit zone.
Armed
If the system is armed, alarm sensor in normal zone type can be triggered immediately if
someone triggers the sensor. It is usually used when there is no operator at surveillance area
Disarmed
If the system is disarmed, alarm events detected from sensors will not result in an alarm except
the fire zone type alarm and arm/disarm tamper. If there are operators at surveillance area, it
is usually disarmed.
Arm/Disarm Tamper Type
Arm/Disarm tamper event triggers if someone cuts the wire between the arm/disarm input and
the transmitter. This event can be triggered immediately no matter which zone is. Arm/Disarm
tamper type has choice of none, SEOL, DEOL. (Please refers to P.100 Tamper Circuit Section
of User Guide)
Arm State
The arm/disarm input circuit type is normal close (NC). The state of the circuit is close, it
indicates disarm of
Tele
Eye RX. Otherwise, the state of the circuit is open, it indicates arm
of
Tele
Eye RX. The arm/disarm input circuit type is normal open (NO). The state of the
circuit is open, it indicates disarm of
Tele
Eye RX. Otherwise, the state of the circuit is close,
it indicates arm of
Tele
Eye RX.