User guide

14797 • November 2004 • Installing the Frame in a Rack
Page 8
INSTALLING THE FRAME IN A RACK
To install the S5000 frame in an equipment rack, see Figure 5 and follow these steps:
1. Determine the placement of the 2 RU frame in the rack.
2. Attach the rack support brackets to the rear rack rails.
3. Attach the rear rack supports to the sides of the frame.
4. Lift the frame into position, inserting the rear rack supports into the slots in the
rack support brackets.
5. Secure the rack ears at the front frame to the rack with rack screws.
Figure 5. Frame Installation
Warning: The power cords supplied with the S5000 provide the only means of AC
mains disconnection. The equipment must be located near the AC source power outlet
and the outlet must be easily accessible to allow power to the equipment to be
disconnected quickly in an emergency.
Note: Be sure to allow unrestricted cooling air flow through the front
and sides of the frame. Frames may be stacked with no space in between.
Do not block air
vents at sides
Cooling Airflow
Rack Support Bracket
Rack Ears
Rear Rack Supports