Operating instructions
Page 35
ProMinent
®
Features of the S2Ca metering pumps
Fig. 16
4
1
7
5
2
6
2
1
4
green/NC
white/NO
brown/C
pacing relay
fault indicating relay
yellow/NO
white/NO
green/NC
brown/C
1
4
3
2
2
3
1
4
5.3 Sockets, symbols and wiring diagram
(1) Socket for two-stage float switch with advance warning and de-activate function (with
function plug*, not illustrated)
(2) External socket for contact or analogue controller with zero volts deactivation via pause
function (with function plug* - not illustrated)
(3) Metering monitor socket for connection of ProMinent
®
metering monitor
(4) Mains switch (1-pin)
(5) Relay cable (fault indicating or pacing relay)
(6) Socket for diaphragm rupture sensor
(7) Mains lead with plug
*Must be plugged in unless cable attached.
Technical data, relay (control version)
Pump type S2Ca
Relay Fault-indicating relay Fault-indicating relay + pulse generator
Relay type Fault-indicating relay pulse generator Fault-indicating relay
Voltage, max: 250 V 50/60 Hz 24 V DC 24 V 50/60 Hz
Current, max. 2 A (ohmic) 100 mA 100 mA
Hook up duration 100 ms
Behaviour see Identcode see Identcode see Identcode
Service life > 200 000 cycles* > 50 x 10
6
(10 V 10 mA) > 200 000 cycles
Relay type Power relay
Voltage, max. 250 V (50/60 Hz)
Current, max. 16 A (ohmic)
Hook up duration
Behaviour see Identcode
Service life > 30 000 cycles*
* in the case of nominal load
The contacts are zero volt.
N/C fault indicating relay - the relay closes immediately after the power is switched on and opens
in the event of a fault.
N/O fault indicating relay, the relay closes in the event of a fault.
Use suitable interference suppression (e.g. RC glands) when connecting inductive loads.