Operating instructions
Page 24
ProMinent
®
Höhe L der S2Ba in Abhängigkeit von der Motorausführung
(Maße in mm)
Standard 1 phase EExe- EExde- Motor Motor with
motor motor motor motor variable speed frequency inverter
Identcode-Merkmal S M, N L1, P1 L2, P2 R V0
L (in mm) 426 427 472 448 523 644
PP/PVC/PTFE
Connection
variations
SS
Anschluss-
varianten
3.1.2 Dimensions Sigma/ 2 S2Ba
Technical data
27
+7
Ø 165
136
120
max. 40
F
K
E
44
6.5
225
A
D 120
28
Ø16
B
Ø G
185
L
Tube nozzle sv d16 S with
thread DIN ISO 228-G3/4
C
PVDF
Fig. 12
61_01-101_00_27-73
Dimensions Sigma/ 2 (in mm)
Type Connection A B C D E F Ø G I K L*
Sigma 04350, 07120, 07220 PVT DN 25 287 234 G11/2"A 118 353 75 156 166 71
Sigma 04350, 07120, 07220 SST DN 25 287 233 G11/2"A 118 345 88 159 140 60
Sigma 12050, 12090, 12130,
16050, 16090, 16130 PVT
DN 15 251 162 G1"A 111 341 72 122 148 63
Sigma 12050, 12090, 12130,
16050, 16090, 16130 SST
DN 15 251 162 G1"A 110 330 88 122 122 53
BA_SI_036_06_10_EN.p65 08.06.2010, 11:38 Uhr24