Operating instructions

Page 21
ProMinent
®
WARNING
Only EX pump: Please thoroughly read the chapter “Important Additions for Metering
Pumps in the EX Area” of the “General Operating Instructions ProMinent Motor Metering
Pumps and Hydraulic Accessories”!
IMPORTANT
With the S3Ba, the customer should install a diaphragm rupture signal monitor with
electrical diaphragm sensors or ensure that the metering pump will stop after a
diaphragm rupture signal.
In the event of diaphragm failure, a signal is triggered as from 2 bar system
backpressure.
Exact pump delivery can no longer be guaranteed after failure of the working diaphragm.
Electrical data for the diaphragm breakage sensor
IMPORTANT
Before commencing operation, install the provided diaphragm breakage sensor together
with the gasket (Item159) and make the electrical connections.
For safety reasons it is advisable to connect a safe low voltage (e.g. EN 60335-1 (SELV)).
a) Switch contact
30 V DC/1 A or 125 V AC/0.6 A or 250 V AC/0.3 A
The diaphragm sensor is a N/C relay.
NOTE
The cable priority is arbitrary.
b) Namur sensor, intrinsically
5-25 V DC, Namur type and/or DIN 60947-5-6, zero volt design.
Rated voltage: 8 V DC (R
i
~ 1 k)
Power consumption:
Active surface, uncovered > 3 mA
Active surface, covered < 2 mA
Rated switching distance: 1.5 mm
The monitor/feeder must be capable of evaluating current changes in order to indicate
diaphragm rupture!
WARNING
Only EX pump: Please thoroughly read the chapter “Important Additions for Metering
Pumps in the EX Area” of the “General Operating Instructions ProMinent Motor Metering
Pumps and Hydraulic Accessories”!
Product description S2Ba/S2Ca
Blue -
Brown +
BA_SI_036_06_10_EN.p65 08.06.2010, 11:38 Uhr21