13.1 Performance data
Type Minimum pump capacity at maximum
back pressure
Maximum
stroke rate
Suction lift Permissible
priming pres‐
sure, suction
side
Connector
size
bar l/h ml/stroke Strokes/min m WS bar R"-DN
16050 PVT 10 50 11.4 73 7 3 1" - 15
16050 SST 16 47 11.4 73 7 3 1" - 15
16090 PVT 10 88 11.4 132 7 3 1" - 15
16090 SST 16 82 11.4 132 7 3 1" - 15
16130 PVT 10 135 10.9 198 7 3 1" - 15
16130 SST 16 124 10.9 198 7 3 1" - 15
07120 PVT 7 120 27.4 73 5 1 20*
07120 SST 7 120 27.4 73 5 1 20*
07220 PVT 7 220 27.7 132 5 1 20*
07220 SST 7 220 27.7 132 5 1 20*
04350 PVT 4 350 29.4 198 5 1 20*
04350 SST 4 350 29.4 198 5 1 20*
All figures refer to water at 20 °C.
The suction lift applies to filled suction line and filled liquid end - when
installed correctly.
* For Sigma types 07120, 07220 and 04350 the valves in the
dosing head are of type DN 25 (G1 1/2). As for these types
of pipes, DN 20 is generally sufficient (see technical data,
suction/discharge side connector), the connector parts that
can be ordered under the identity code (e.g. inserts) are
already reduced to DN 20, i.e. piping and accessories can be
installed in DN 20.