Datasheet
19
<<CHART
A
>>
Camera
Lens Type
Exp. Mode
Metering
TTL System
Note
Conf
Dist
D, G Type
All Modes
All Modes
3-D Multi-Sensor
BL
AF lens other than
D, G type
All Modes
All Modes
Multi-Sensor BL
1
F5
F100
F90X/N90ser.
F80/N80ser.
F70D/N70
F75/N75
Without Built in CPU
A/M
Modes
Center-weighted,
Spot Metering
Center Weighted /
Spot Fill-Flash
Can switch to TTL Mode. With
F5, F100, F80, series Cameras
spot metering system is always
TTL.
2
%
Matrix Pattern
TTL BL
With Built-in CPU
All Modes
Center-weighted,
Spot Metering
Center Weighted /
Spot Fill-Flash
1
F4 Series
F-801S/N8008S
F-801/N8008
F65/N65
Pronea 600i
Without
Built-in CPU
A/M
Modes
Center-weighted,
Spot Metering
Center
Weighted/Spot
Fill-Flash
Can switch to TTL Mode. TTL BL
can work with only F4 series, AF
F3, Ai-S, Ai, Series E lens. Spot
metering system of F4 is always
TTL. Pronea 600i will be TTL,
when exposure mode is “M”.
Center Weighted BL cannot work.
2
Matrix Pattern
TTL BL
With Built-in CPU
All Modes
Center-weighted,
Spot Metering
Center Weighted /
Spot Fill-Flash
F601/N6006
F-601M
Without
Built-in CPU
A/M
Modes
Center-weighted,
Spot Metering
Center Weighted /
Spot Fill-Flash
Spot Metering cannot use with
F-601M
2
With Built-in CPU
P/S
A/M
TTL BL
If exposure mode is “M”, it will be
Center Weighted/Spot Fill-Flash
2
F60D/N60
F50D/N50
F-401X/4004S
Without
Built-in CPU
M
Center Weighted /
Spot Fill-Flash
2
P
TTL Programmed
Built-in CPU lens
,Ai-S, Ai, Series E,
AF F3 Lens
A/M
TTL
F501/N2020
F301/N2000
Except above
lenses
A/M
TTL
2
P/S
TTL Programmed
With Built-in CPU
A/M
TTL
2
F401S/N4004S
F401/N4004
Without Built-in CPU
M
TTL
2
FA, FE2
FG, F3, FM3
With Built-in CPU;
Without Built-in CPU
A/M
TTL
2
Confirm Distance:
1
: Flash’s LCD panel will show F-number and working distance of flash.
2
: Set the F-number on the flash to be the same as camera, and check the available working distance range
on the LCD panel. To set the F-number on Flash, push the SEL button until the F-number blinks, and use + or –
button to set the F-number. Then press the SEL button again. The F-number will stop blinking.
` When you use Digital SLR cameras, functions will vary depending on the lens type and combinations of
exposure modes, same as F5 and F100 group. (However, all TTL exposure functions will be the D-TTL
(i-TTL) system).
LIMITS OF CONTINUOUS SHOOTING
To prevent overheating of the flash’s circuitry, please do not use your Flash unit for at least 10minutes after
using the number of flash exposures, shown in the below table have been made in quick succession.
Mode
Number of Flash Exposures
TTL, M(1/1,1/2)
15 Continuous Flash Shots
M(1/4, 1/8)
20 Continuous Flash Shots
M(1/16-1/32)
40 Continuous Flash Shots
Multi
10 Cycle
MANUAL FLASH OPERATION
Manual flash is provided when shooting the subjects when the correct,
Exposure is difficult to obtain in the TTL mode. In the manual flash
mode, you can set the flash power level from 1/1 (full) to 1/64 (0.3
stop) power in one step increments.
1. Set the camera’s exposure mode (A, M modes).
2. Press the MODE button on the flash unit to select M.
3. The Guide Number value blinks, when you press the SEL button