Programming Guide

Table Of Contents
SIGLENT
62 SVA1000X Programming Guide
Parameter
Type
None
Parameter
Range
None
Return
None
Default
None
Menu
Meas > Spectrum Monitor > Meas Setup > Restart
Example
:SPECtrogram:RESTart
3.7.6 Third-order Intercept PointTOI
3.7.6.1 Query Third-order Intercept Point result(:MEASure:TOI?)
Command
Format
:MEASure:TOI?
Instruction
Gets the result of Third-order Intercept Point
Parameter
Type
None
Parameter
Range
None
Return
Float
Default
None
Menu
Meas > TOI
Example
:MEASure:TOI?
3.7.6.2 Query Third-order Intercept Point(:MEASure:TOI:IP3?)
Command
Format
:MEASure:TOI:IP3?
Instruction
Gets the min intercept of the Lower TOI(Lower 3rd) and the Upper TOI(Upper
3rd)
Parameter
Type
None
Parameter
Range
None
Return
Float
Default
None
Menu
Meas > TOI
Example
:MEASure:TOI:IP3?
3.8 Trigger Subsystem
3.8.1 Trigger Type (:TRIGger[:SEQuence]:SOURce)
Command
Format
:TRIGger[:SEQuence]:SOURce IMMediate|VIDeo|EXTernal
:TRIGger[:SEQuence]:SOURce?
Instruction
Specifies the source (or type) of triggering used to start a measurement.
Gets trigger type.
Parameter
Type
Enumeration