Programming Guide

Table Of Contents
SIGLENT
54 SVA1000X Programming Guide
Type
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
OFF
Menu
Limit > Setup > Fail to stop
Example
:CALCulate:LLINe:FAIL:STOP OFF
3.7 Measurement Subsystem
3.7.1 ACPR Subsection
3.7.1.1 Main Channel ([:SENSe]:ACPRatio:BWIDth:INTegration)
Command
Format
[:SENSe]:ACPRatio:BWIDth:INTegration <freq>
[:SENSe]:ACPRatio:BWIDth:INTegration?
Instruction
Specifies the range of integration used in calculating the power in the main
channel.
Gets the range of integration used in calculating the power in the main channel.
Parameter
Type
Float, unit: Hz, KHz, MHz, GHz
Parameter
Range
100 Hz~1.5 GHz
Return
Float, unit: Hz
Default
1MHz
Menu
Meas > ACPR > Meas Setup > Main Channel
Example
INSTrument:MEASure ACPR
:ACPRatio:BWIDth:INTegration 20 MHz
3.7.1.2 Adjacent Channel Bandwidth
([:SENSe]:ACPRatio:OFFSet:BWIDth[:INTegration])
Command
Format
[:SENSe]:ACPRatio:OFFSet:BWIDth[:INTegration] <freq>
[:SENSe]:ACPRatio:OFFSet:BWIDth[:INTegration]?
Instruction
Specifies the bandwidth used in calculating the power in the adjacent channel.
Gets the bandwidth used in calculating the power in the adjacent channel.
Parameter
Type
Float, unit: Hz, KHz, MHz, GHz
Parameter
Range
100 Hz~1.5 GHz
Return
Float, unit: Hz
Default
1MHz
Menu
Meas > ACPR > Meas Setup > Adjacent Chn
Example
:ACPRatio:OFFSet:BWIDth 20 MHz
3.7.1.3 Channel Space
([:SENSe]:ACPRatio:OFFSet[:FREQuency])
Command
[:SENSe]:ACPRatio:OFFSet[:FREQuency] <freq>