Programming Guide

Table Of Contents
SIGLENT
SVA1000X Programming Guide 45
Type
Parameter
Range
-200.0 dBm~ 200.0 dBm
Return
Float, unit: dBm
Default
-160.0 dBm
Menu
Peak > Search Config > Peak Threshold
Example
:CALCulate:MARKer:PEAK:THReshold -50
3.6.1.18 Peak Excursion (:CALCulate:MARKer:PEAK:EXCursion)
Command
Format
:CALCulate:MARKer:PEAK:EXCursion <value>
:CALCulate:MARKer:PEAK:EXCursion?
Instruction
Specifies the minimum signal excursion above the threshold for the internal
peak identification routine to recognize a signal as a peak.
Parameter
Type
Float, unit: dB
Parameter
Range
0 ~ 200.0dB
Return
Float, unit: dB
Default
0 dB
Menu
Peak > Search Config > Peak Excursion
Example
:CALCulate:MARKer:PEAK:EXCursion 10
3.6.1.19 Peak Table (:CALCulate:MARKer:PEAK:TABLe)
Command
Format
:CALCulate:MARKer:PEAK:TABLe ON|OFF|0|1
:CALCulate:MARKer:PEAK:TABLe?
Instruction
Toggles the peak table between on and off.
Gets the status of the peak table.
Parameter
Type
Boolean
Parameter
Range
ON|OFF|0|1
Return
0|1
Default
0
Menu
Peak > Peak Table
Example
:CALCulate:MARKer:PEAK:TABLe ON
3.6.1.20 Continuous Peaking Marker
(:CALCulate:MARKer[1]|2|3|4|5|6|7|8:CPEak[:STATe])
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:CPEak[:STATe] OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:CPEak[:STATe]?
Instruction
Toggles the continuous peak search function between on and off.
Gets the continuous peak search function state.
Parameter
Type
Boolean
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
None
Menu
Peak > Cont Peak