Programming Guide

Table Of Contents
SIGLENT
SVA1000X Programming Guide 25
Default
150 MHz
Menu
Frequency > Freq Step
Example
:FREQuency:CENTer:STEP 2 MHz
3.5.1.5 Center Frequency Step Mode
([:SENSe]:FREQuency:CENTer:STEP:AUTO)
Command
Format
[:SENSe]:FREQuency:CENTer:STEP:AUTO OFF|ON|0|1
[:SENSe]:FREQuency:CENTer:STEP:AUTO?
Instruction
Specifies whether the step size is set automatically based on the span.
Gets center frequency step mode.
Parameter
Type
Boolean
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
ON
Menu
Frequency > Freq Step
Example
:FREQuency:CENTer:STEP:AUTO OFF
3.5.1.6 Sets CF→Step ([:SENSe]:FREQuency:CENTer:SET:STEP)
Command
Format
[:SENSe]:FREQuency:CENTer:SET:STEP
Instruction
Sets step value equal to center frequency.
Parameter
Type
None
Parameter
Range
None
Return
None
Default
None
Menu
Frequency > CF→Step
Example
:FREQuency:CENTer:SET :STEP
3.5.1.7 Frequency Span ([:SENSe]:FREQuency:SPAN)
Command
Format
[:SENSe]:FREQuency:SPAN <freq>
[:SENSe]:FREQuency:SPAN?
Instruction
Sets the frequency span. Setting the span to 0 Hz puts the analyzer into zero
span.
Gets span value.
Parameter
Type
Float, unit: Hz, KHz, MHz, GHz
Parameter
Range
0 Hz, 100 Hz ~ 1.5GHz
Return
Float, unit: Hz
Default
1.5 GHz
Menu
Span > Span
Example
:FREQuency:SPAN 1 GHz