Data Sheet
SSG3000X RF Generator datasheet
WWW.SIGLENT.COM
Frequency modulation
Modulation source internal, external, internal +external
Maximum deviation N*1 MHz (typ.)
Resolution 0.1% of set deviation or 1 Hz, whichever is larger
FM deviation error Fmod=1 kHz, internal <(2% of setting + 20 Hz)
FM distortion
Fmod =1 kHz,
deviation=N*1 MHz
<0.5% (nom.)
Modulation frequency response 10 Hz~100 kHz <3 dB (nom.)
Phase modulation
Modulation source internal, external, internal + external
Maximum deviation N*5 rad
Resolution 0.1% of set deviation or 0.01 rad, whichever is larger
ΦM deviation error
Fmod=1 kHz, internal,
deviation≤ N*5 rad
<(2% of setting + 0.05 rad)
ΦM distortion Fmod=1 kHz, deviation≤ N*5 rad <0.5% (nom.)
Modulation frequency response 10 Hz~100 kHz <3 dB (nom.)
Pulse modulation
Modulation source internal, external
On/off ration 1 MHz <f<3.2 GHz >70 dBc
Raise/fall time (10% / 90%) 10% to 90% of RF amplitude <50 ns
Pulse repetition time setting range 40 ns~300 s
Pulse generator
Pulse modes single pulse, double pulse
Pulse source internal, external
Pulse polarity normal, inverse
Pulse period
setting range 40 ns~300 s
resolution of setting 10 ns
Pulse width
setting range 20 ns~300 s
resolution of setting 10 ns
Double pulse Delay
setting range 20 ns~300 s
resolution of setting 10 ns
#2 Width
setting range 20 ns~300 s
resolution of setting 10 ns
Trigger modes auto, keyboard, external trigger, external gate trigger, bus
Trig polarity normal, inverse (used in external gate trigger mode)
Trigger Slop positive, negative (used in external trigger mode)
External trigger delay 140 ns~300 s
External trigger delay resolution
of setting
10 ns
Pulse train generator (SSG3000X-PT)
Number of pulses 1~2047
Number of repetitions per pulse 1 to 65535
Pulse on time and off time
setting range
20 ns~300 s
Pulse on time and off time
setting resolution
10 ns