Programming Guide
Table Of Contents
- 1. Programming Overview
- 2. SCPI Overview
- 3. Commands that are Common to All Modes
- 4. Spectrum Analyzer
- 5. Modulation Analyzer
- 6. Programming Examples
SIGLENT
70 SSA3000X Plus Programming Guide
Example
INSTrument:MEASure ACPR
:ACPRatio:BWIDth:INTegration 20 MHz
Command
Format
[:SENSe]:ACPRatio:OFFSet:BWIDth[:INTegration] <freq>
[:SENSe]:ACPRatio:OFFSet:BWIDth[:INTegration]?
Instruction
Specifies the bandwidth used in calculating the power in the adjacent
channel.
Gets the bandwidth used in calculating the power in the adjacent channel.
Parameter
Type
Float, unit: Hz, kHz, MHz, GHz
Parameter
Range
100 Hz~1.5 GHz
Return
Float, unit: Hz
Default
1MHz
Menu
Meas > ACPR > Meas Setup > Adjacent Chn
Example
:ACPRatio:OFFSet:BWIDth 20 MHz
Command
Format
[:SENSe]:ACPRatio:OFFSet[:FREQuency] <freq>
[:SENSe]:ACPRatio:OFFSet[:FREQuency]?
Instruction
Sets the space value between the center frequency of main channel power
and that of the adjacent channel power.
Gets adjacent channel space
Parameter
Type
Float, unit: Hz, kHz, MHz, GHz
Parameter
Range
100 Hz~700 MHz
Return
Float, unit: Hz
Default
3MHz
Menu
Meas > ACPR > Meas Setup > Adj Chn Space
Example
:ACPRatio:OFFSets 20 MHz
Command
Format
:MEASure:ACPRatio:MAIN?
Instruction
Return the main channel power of ACPR measurement.
Parameter
Type
None
Parameter
Range
None
Return
Float, unit: dBm
Default
None
Menu
Meas > ACPR
Example
:MEASure:ACPRatio:MAIN?