Programming Guide

Table Of Contents
SIGLENT
34 SSA3000X Plus Programming Guide
Default
20 dB
Menu
Amplitude > Attenuator
Example
:POWer:ATTenuation 10
Command
Format
[:SENSe]:POWer[:RF]:ATTenuation:AUTO OFF|ON|0|1
[:SENSe]:POWer[:RF]:ATTenuation:AUTO?
Instruction
This command turns on/off auto input port attenuator state.
Gets input port attenuator state.
Parameter
Type
Boolean
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
ON
Menu
Amplitude > Attenuator
Example
:POWer:ATTenuation:AUTO?
Command
Format
[:SENSe]:POWer[:RF]:GAIN[:STATe] OFF|ON|0|1
[:SENSe]:POWer[:RF]:GAIN[:STATe]?
Instruction
Turns the internal preamp on/off.
Gets preamp on-off state.
Parameter
Type
Boolean
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
OFF
Menu
Amplitude > Preamp
Example
:POWer:GAIN ON
Command
Format
:DISPlay:WINDow:TRACe:Y:SCALe:RLEVel:OFFSet <value>
:DISPlay:WINDow:TRACe:Y:SCALe:RLEVel:OFFSet?
Instruction
Sets reference offsets.
Gets reference offsets.
Parameter
Type
Float
Parameter
Range
-100dB~100dB
Return
Float, unit: dB
Default
0dB
Menu
Amplitude > Ref OffSets