Data Sheet

WWW.SIGLENT.COM
SSA3000X Spectrum Analyzer Data Sheet
Amplitude Characteristic
Amplitude and Level
Measurement range DANL to +10 dBm, 100 kHz~1 MHz, preamplier off
DANL to +20 dBm, 1 MHz~3.2 GHz, preamplier off
Reference level -100 dBm to +30 dBm, 1 dB steps
Preamplier 20 dB (nom.), 9 kHz~3.2 GHz
Input attenuation 0~51 dB, 1 dB steps
Maximum input DC voltage +/- 50 V
DC
Maximum series RF power 33 dBm, 3 minutes, input attenuation >20 dB
Displayed Average Noise Level (DANL)
20
~30
,attenuation = 0 dB, sample detector, trace average >50
Preamp off
RBW=10 Hz Normalization to 1Hz
9 kHz~100 kHz -100 dBm (nom.) -110 dBm (nom.)
100 kHz ~1 MHz -97 dBm, -101 dBm (typ.) -107 dBm,-111 dBm (typ.)
1 MHz~10 MHz -122 dBm, -126 dBm (typ.) -132 dBm,-136 dBm (typ.)
10 MHz~200 MHz -127 dBm,-131 dBm (typ.) -137 dBm,-141 dBm (typ.)
200 MHz~2.1 GHz -125 dBm, -129 dBm (typ.) -135 dBm,-139 dBm (typ.)
2.1 GHz~3.2 GHz -116 dBm, -122 dBm (typ.) -126 dBm,-132 dBm (typ.)
Preamp on
9 kHz~100 kHz -107 dBm (nom.) -117 dBm (nom.)
100 kHz ~1 MHz -122 dBm, -127 dBm (typ.) -132 dBm,-137 dBm (typ.)
1 MHz~10 MHz -138 dBm, -144 dBm (typ.) -148 dBm,-154 dBm (typ.)
10 MHz~200 MHz -146 dBm, -151 dBm (typ.) -156 dBm,-161 dBm (typ.)
200 MHz~2.1 GHz -145 dBm, -148 dBm (typ.) -155 dBm,-158 dBm (typ.)
2.1 GHz~3.2 GHz -135 dBm, -139 dBm (typ.) -145 dBm,-149 dBm (typ.)
Phase Noise
20
~30
,fc=1 GHz
Phase noise
<-95 dBc/Hz @10 kHz offset, <-98 dBc/Hz (typ.)
<-96 dBc/Hz @100 kHz offset,<-97 dBc/Hz (typ.)
<-115 dBc/Hz @1 MHz offset, <-117 dBc/Hz (typ.)
Level Display
Logarithmic level axis 10 dB to 100 dB
Linear level axis 0 to reference level
Units of level axis dBm, dBmV, dBμV, V, W
Number of display points 751
Number of traces 4
Trace detectors Positive-peak, Negative-peak, Sample, Normal, Average (Voltage/RMS/Video) , Quasi-peak (with EMI option)
Trace functions Clear write, Max Hold, Min Hold, View, Blank, Average
Frequency Response
20
to 30
, 30% to 70% relative humidity, attenuation = 20 dB, reference frequency 50 MHz
Preamp off ±0.8 dB,
±0.4 dB, (typ.)
Preamp on ±0.9 dB,
±0.5 dB, (typ.)
Error and Accuracy
Resolution bandwidth switching
uncertainty
10 kHz RBW
Logarithmic resolution ±0.2 dB, liner resolution ±0.01, nominal
Input attenuation switching
uncertainty
20
to 30
, fc = 50 MHz, preamp off, Relative to 20 dB, 1 to 51 dB attenuation
±0.5 dB
Absolute amplitude accuracy
20
to 30
, fc = 50 MHz, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB, 95th percentile reliability
preamp off ±0.4 dB, input signal -20 dBm
preamp on ±0.5 dB, input signal -40 dBm
Total amplitude accuracy
20
to 30
, Fc>100 kHz, input signal -50 dBm~0 dBm, RBW = 1 kHz, VBW = 1 kHz, peak detector, attenuation = 20 dB,
preamp off, 95th percentile reliability
± 0.7 dB
RF input VSWR
input attenuation 10 dB, 1 MHz~3.2 GHz
<1.5,nom