Programming Guide

Table Of Contents
SIGLENT
SSA3000X Plus Programming Guide 59
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:CPEak[:STATe] OFF|ON|0|1
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:CPEak[:STATe]?
Instruction
Toggles the continuous peak search function between on and off.
Gets the continuous peak search function state.
Parameter
Type
Boolean
Parameter
Range
OFF|ON|0|1
Return
0|1
Default
None
Menu
Peak > Cont Peak
Example
:CALCulate:MARKer1:CPEak ON
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:MAXimum
Instruction
Performs a peak search based on the search mode settings.
(based on the search mode settings, include: peak search mode, peak
threshold and peak excursion, Reference Commands:
:CALCulate:MARKer:PEAK:SEARch:MODE
:CALCulate:MARKer:PEAK:THReshold
:CALCulate:MARKer:PEAK: EXCursion)
Parameter
Type
None
Parameter
Range
None
Return
None
Default
None
Menu
Peak
Example
:CALCulate:MARKer4:MAXimum
Command
Format
:CALCulate:MARKer[1]|2|3|4|5|6|7|8:MAXimum:NEXT
Instruction
Places the selected marker on the next highest signal peak of the current
marked peak.
(based on the search mode settings, include: peak search mode, peak
threshold and peak excursion, Reference Commands:
:CALCulate:MARKer:PEAK:SEARch:MODE
:CALCulate:MARKer:PEAK:THReshold
:CALCulate:MARKer:PEAK: EXCursion)
Parameter
Type
None
Parameter
Range
None
Return
None