Programming Guide
Table Of Contents
- 1. Programming Overview
- 2. SCPI Overview
- 3. Commands that are Common to All Modes
- 4. Spectrum Analyzer
- 5. Modulation Analyzer
- 6. Programming Examples
SIGLENT
SSA3000X Plus Programming Guide 43
Example
:TRIGger:VIDeo:LEVel 0.5 dBm
Command
Format
:TRIGger[:SEQuence]:RFBurst:SLOPe POSitive|NEGative
:TRIGger[:SEQuence]:RFBurst:SLOPe?
Instruction
This command activates the trigger condition that allows the next sweep to
start when the external voltage (connected to EXT TRIG IN connector)
passes through approximately 1.5 volts. The external trigger signal must be a
0V to +5V TTL signal. This function only controls the trigger polarity (for
positive or negative-going signals).
Gets Trigger edge.
Parameter
Type
Enumeration
Parameter
Range
POSitive: positive edge.
NEGative: negative edge.
Return
Enumeration
Default
POSitive
Menu
Trigger > External Trigger
Example
:TRIGger:RFBurst:SLOPe POSitive
4.5 Bandwidth Subsection
[:SENSe]:BWIDth[:RESolution]
[:SENSe]:BWIDth[:RESolution]:AUTO
[:SENSe]:BWIDth:VIDeo
[:SENSe]:BWIDth:VIDeo:AUTO
[:SENSe]:BWIDth:VIDeo:RATio
[:SENSe]:BWIDth:VIDeo:RATio:CONfig?
[:SENSe]:FILTer:TYPE
Command
Format
[:SENSe]:BWIDth[:RESolution] <freq>
[:SENSe]:BWIDth[:RESolution]?
Instruction
Specifies the resolution bandwidth. For numeric entries, all RBW types
choose the nearest (arithmetically, on a linear scale, rounding up) available
RBW to the value entered.
Parameter
Type
Discrete
Parameter
Range
1Hz, 3Hz, 10 Hz, 30 Hz, 100 Hz, 300 Hz, 1 kHz, 3 kHz, 10 kHz, 30 kHz, 100
kHz, 300 kHz, 1 MHz
Return
Float, unit: Hz
Default
1 MHz
Menu
BW > RBW
Example
:BWIDth 1 kHz