Programming Guide
Table Of Contents
- 1. Programming Overview
- 2. SCPI Overview
- 3. Commands that are Common to All Modes
- 4. Spectrum Analyzer
- 5. Modulation Analyzer
- 6. Programming Examples
SIGLENT
40 SSA3000X Plus Programming Guide
Parameter
Range
ACCUracy|NORMal
Return
Enumeration
Default
NORMal
Menu
Sweep > Sweep Rule
Example
:SWEep: SPEed NORMal
Command
Format
[:SENSe]:SWEep:COUNt <integer>
[:SENSe]:SWEep:COUNt?
Instruction
Sets sweep numbers, when single sweep on.
Gets sweep numbers, when single sweep on.
Parameter
Type
Integer
Parameter
Range
1 ~ 99999
Return
Integer
Default
1
Menu
Sweep > Numbers
Example
:SWEep:COUNt 10
Command
Format
[:SENSe]:QPD:DWELl:TIME < time >
[:SENSe]:QPD:DWELl:TIME?
Instruction
Sets QPD Time
Gets QPD Time
Parameter
Type
Float, unit: s, ms, us
Parameter
Range
0us ~ 10s(qusai-peak: 900us ~ 30ks)
Return
Float, unit: s
Default
50ms
Menu
Sweep > QPD Time
Example
:QPD:DWELl:TIME 10s
Command
Format
:INITiate[:IMMediate]
Instruction
Restart the current sweep.
Parameter
Type
None
Parameter
Range
None
Return
None