2.6 Timer
The SPD1000X provides a timer function. The timer can save five sets of
settings, each set independent of the others. The user can set arbitrary
parameters within the voltage, current, and dwell time values. The timer
supports continuous output, with the longest time-out time of up to 10000 s.
Set the timer parameter
Method 1:
1. Press Timer/Wave to enter the Timer Setup interface, and the
indicator will illuminate.
2. Pressing the arrow keys, move the cursor to select the desired
parameter (voltage/current/time).
3. Rotate the multi-function knob or press the left and right buttons for 1
second or longer period to set the corresponding value. The Fine
button can be used to move between the digits in any highlighted field.
4. Press Timer/Wave again to exit the Timer interface.