Programming Guide
Digital Oscilloscopes Series
93
DISPLAY
PANEL_SETUP, PNSU
Command /Query
DESCRIPTION
The PANEL_SETUP command complements the
*SAV or *RST commands.
PANEL_SETUP allows you to archive panel setups
in encoded form on external storage media. Only
setup data read by the PNSU? query can be
recalled.
COMMAND SYNTAX
PaNel_SetUp <setup>
<setup> : = A setup previously read by PNSU?
QUERY SYNTAX
PaNel_SetUp?
RESPONSE FORMAT
PaNel_SetUp <setup>
EXAMPLE
The following instruction saves the oscilloscope‘s
current panel setup in the file PANEL.SET:
Command message:
PNSU
RELATED COMMANDS
*RCL, *SAV