<polarity>: = {PO,NE}
PO means positive. NE means negative.
CHAR, <characteristics>: is used to set the
standard. If you want to set it, the <trig_type>
must be set to TV.
<characteristics>:={NTSC, PALSEC}
SYNC,<sync_type>: is used to set sync. If you
want to set it. You must set <trig_type> to TV
<sync_type> : = {AL,LN,OF,EF}
AL means all lines; LN means line num; OF
means odd field; EF means even field.
LINE,<line>: is used to set the line num. if you
want to set it. The SYNC must be set to
LINENUM
VERT,<vertical>: is used to set vertical. If you
Want to set it. You must set <trig_type> SLEW
<vertical>: = {UP,DOWN,BOTH}
Note:
This format is suitable for non-SPO models.
RELATED COMMANDS
TRIG_COUPLING, TRIG_DELAY,
TRIG_LEVEL, TRIG_MODE, TRIG_SLOPE