Type Model Picture Specications
Passive Probe
PB470
70 MHz Bandwidth
1 X/10 X,1 M/10 Mohm, 300 V/600 V
PP510
100 MHz Bandwidth
1 X/10X, 1 M/10 Mohm, 300 V/600 V
PP215
200 MHz Bandwidth
1 X/10X,1 M/10 Mohm, 300 V/600 V
Current Probe
CP4020
Bandwidth: 100 KHz, Max. continuous current: 20 Arms, Peak current: 60 A
Switch Ratio: 50 mV/A, 5 mV/A, Accuracy: 50 mV/A (0.4A-10ApK)±2%,
5 mV/A (1A-60ApK) ±2%, 9 V battery source
CP4050
Bandwidth: 1 MHz; Maximum continuous current 50 Arms;
Peak current 140 A; Switching ratio: 500 mV/A; 50 mV/A;
DC measurement accuracy: 500 mV/A (20 mA-14 ApK) ±3%±20 mA;
50 mV/A (200 mA-100 ApK )±4%± 200 mA;
50 mV/A (100 A-140 ApK)±15% max; 9 V battery-powered
CP4070
Bandwidth: 150 KHz; Maximum continuous current 70 Arms;
Peak current 200 A;Switching ratio: 50 mV/A; 5 mV/A;
DC measurement accuracy: 50 mV/A (0.4 A-10 ApK) ±2%,
±5 mV/A
(1 A-200 ApK)±2%; 9 V battery-powered
CP4070A
Bandwidth: 300 KHz; Maximum continuous current 70 Arms;
Peak current 200 A;Switching ratio: 100 mV/A;10 mV/A;
DC measurement accuracy: 100 mV/A (50 mA-10 ApK) ±3%±50 mA;
10 mV/A (500 mA-40 ApK) ±4%±50 mA;
10 mV/A (40 A-200 ApK) ±15%max; 9 V battery-powered
CP5030
Bandwidth: 50 MHz; Maximum continuous current 30 Arms;
Peak current 50 A;Switching ratio: 100 mV/A, 1 V/A;
AC/DC measurement accuracy: 1 A (±1%±1 mA);
100 mV/A (±1%±10 mA); Standard DC12 V/1.2 A power adapter
CP5030A
Bandwidth: 100 MHz; Maximum continuous current 30 Arms;
Peak current 50 A;Switching ratio: 100 mV/A, 1 V/A;
AC/DC measurement accuracy: 1 A (±1%±1 mA);
100 mV/A (±1%±10 mA); Standard DC12 V/1.2 A power adapter
CP5150
Bandwidth: 12 MHz; Maximum continuous current 150 Arms;
Peak current 300 A;Switching ratio: 100 mV/A, 1 V/A;
AC/DC measurement accuracy: 100 mV/A(±1%±1 mA);
10 mV/A (±1%±10 mA); Standard DC12 V/1.2 A power adapter
CP5500
Bandwidth: 5 MHz; Maximum continuous current 500 Arms; Peak current750
A; Switching ratio: 100 mV/A, 10 mV/A;
AC/DC measurement accuracy: 100 mV/A (±1%±1 mA);
10 mV/A (±1%±10 mA); Standard DC12 V/1.2 A power adapter
High Voltage
Differential
Probe
DPB4080
Bandwidth: 50 MHz;
Maximum input differential voltage 800 V (DC + Peak AC);
Range selection (attenuation ratio):10 X/100 X; Accuracy: ±1%;
Standard DC 9 V/1 A power adapter
DPB5150
Bandwidth: 70 MHz;
Maximum input differential voltage 1500 V (DC + Peak AC);
Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%;
Standard 5 V/1 A USB power adapter
DPB5150A
Bandwidth: 100 MHz;
Maximum input differential voltage 1500 V (DC + Peak AC);
Range selection (attenuation ratio): 50 X/500 X; Accuracy: ±2%;
Standard 5 V/1 A USB power adapter