Quick Start Guide

Chapter 2 Function and Features SIGLENT
SDL1000X User Manual 59
the data file in ".CSV" format to the USB storage device.
This will prompt you to name the file. The load will begin to graph the
data as well as write it to the USB memory stick. When you are
recording data, the corresponding flag will display in the top of the
interface :
The flag will disappear after pressing the Record key again.
6. Playback
Press PlayBack to play back the recorded data files.
(1) After stopping a recording, pressPlayback to enter the playback
interface.
(2) Press the File softkey to open the file dialog window.
(3) Use the keypad arrows to navigate and select the data file in .CSV
format that you wish to replay.
(4) Press the Read key , the instrument will read the selected data file
and display in the waveform display interface.
Tip
The recording function and palyback function can not be enabled at
the same time.
Restore
The load can save various types of files to internal or external
memories. You can recall and read them when necessary. The load
supports an internal non-volatile memory (Local(C:) and an external
memory (USB(D:). Disk D is only available when a USB storage device
is detected over the USB HOST interface on the front panel.