Programming Guide
SIGLENT
SDL1000X Programming Guide 54
Command
Format
TIME:TEST:VOLTage:HIGH {< value > | MINimum | MAXimum
| DEFault}
Description
Sets the V_High voltage in the time measurement function
(SLMT).
Example
TIME:TEST:VOLTage: HIGH 10.000
Command
Format
TIME:TEST:VOLTage:HIGH?
Description
Query the V_High voltage in the time measurement function
(SLMT).
Example
TIME:TEST:VOLTage: HIGH?
Response
150.00
Command
Format
TIME:TEST:RISE?
Description
Query the voltage rise time in the time measurement function
(SLMT).
Example
TIME:TEST:RISE?
Response
0.020
Command
Format
TIME:TEST:FALL?
Description
Query the voltage descending time in the time measurement
function (SLMT).
Example
TIME:TEST: FALL?
Response
0.030
3.5 LAN Interface Subsystem Command
Command
Format
LAN:LINK?
Description
Query whether the LAN interface of the electronic load had been
connect to the network.
Example
LAN:LINK?
Response
0