Programming Guide

SIGLENT
SDL1000X Programming Guide 48
Command
Format
[:SOURce]: EXT:INPUT [:STATe]?
Description
Query whether the external control switch of the electronic load is
enabled.
Example
:SOURce: EXT:INPUT:STATe?
Response
0
Command
Format
[:SOURce]:CURRent:PROTection:STATe {ON | OFF | 0 | 1}
Description
Sets whether enable the current protection switch of the electronic
load.
Example
:SOURce:CURRent:PROTection:STATe ON
Command
Format
[:SOURce]: EXT:INPUT [:STATe]?
Description
Query whether the current protection switch of the electronic load
is enabled.
Example
:SOURce: EXT:INPUT:STATe?
Response
0
Command
Format
[:SOURce]:CURRent:PROTection:LEVel {< value > | MINimum |
MAXimum | DEFault}
Description
Sets the threhold value of the current protection of the electronic
load after enable the current protection function.
Example
:SOURce:CURRent:PROTection:LEVel 7.00
Command
Format
[:SOURce]:CURRent:PROTection:LEVel?
Description
Query the threhold value of the current protection of the electronic
load.
Example
:SOURce:CURRent:PROTection:LEVel?
Response
8.000
Command
Format
[:SOURce]:CURRent:PROTection:DELay {< value > | MINimum |
MAXimum | DEFault}
Description
Sets the delay time of the current protection of the electronic load .
Example
:SOURce:CURRent:PROTection:DELay 2.00