Programming Guide
SIGLENT
SDL1000X Programming Guide 46
Command
Format
[:SOURce]:WAVE:TIME?
Description
Query the window time in Waveform Display Function. Its unit is
“s”
Example
:SOURce:WAVE:TIME?
Response
3600
Command
Format
[:SOURce]:WAVE:MODE {CURRent | VOLTage | POWer |
RESistance }
Description
Sets different data type include I, U, R and P displayed in
Waveform Display Function.
Example
:SOURce]:WAVE:MODE CURRent
Command
Format
[:SOURce]:WAVE:MODE?
Description
Query the displayed data type in Waveform Display Function.
Example
:SOURce]:WAVE:MODE?
Response
VOLTAGE
Command
Format
[:SOURce]:WAVE:PAUSE {ON | OFF | 0 | 1}
Description
Sets whether pause the waveform displayed in the Waveform
Display Function.
Example
:SOURce:WAVE:PAUSE ON
Command
Format
[:SOURce]:WAVE:PAUSE?
Description
Query whether the waveform displayed in the Waveform Display
Function is paused.
Example
:SOURce:WAVE:PAUSE?
Response
1
Command
Format
[:SOURce]:WAVE:DISPlay {ON|OFF|0|1}
Description
Enter the Waveform Display Function of the electronic load.
Example
:SOURce:WAVE:DISPlay ON