Programming Guide
SIGLENT
SDL1000X Programming Guide 30
Description
Sets the cut-off discharging time value in BATTERY function.
Example
:SOURce:BATTery:TIMer DEFault
Command
Format
[:SOURce]:BATTery:TIMer?
Description
Query the cut-off discharging time value in BATTERY function.
Example
:SOURce:BATTery:TIMer?
Response
999.0000
Command
Format
[:SOURce]:BATTery:VOLTage:STATe {ON | OFF | 0 | 1}
Description
Sets whether use the cut-off voltage as the terminating condiation
in BATTERY function.
Example
:SOURce:BATTery:VOLTage:STATe ON
Command
Format
[:SOURce]:BATTery:VOLTage:STATe?
Description
Query whether the cut-off voltage is the terminating condiation in
BATTERY function.
Example
:SOURce:BATTery:VOLTage:STATe?
Response
0
Command
Format
[:SOURce]:BATTery:CAPability:STATe {ON | OFF | 0 | 1}
Description
Sets whether use the cut-off capacitance as the terminating
condiation in BATTERY function.
Example
:SOURce:BATTery: CAPability:STATe OFF
Command
Format
[:SOURce]:BATTery:CAPability:STATe?
Description
Query whether the cut-off capacitance is the terminating condiation
in BATTERY function.
Example
:SOURce:BATTery: CAPability:STATe?
Response
1
Command
Format
[:SOURce]:BATTery:TIMer:STATe{ON | OFF | 0 | 1}
Description
Sets whether use the discharging time as the terminating condiation
in BATTERY function.
Example
:SOURce:BATTery: TIMer:STATe ON