Programming Guide
SIGLENT
SDL1000X Programming Guide 29
Format
Description
Query the resistor range in BATTERY function.
Example
:SOURce:BATTery:IRANGe?
Response
MIDDLE
Command
Format
[:SOURce]:BATTery:LEVel <value>
Description
Sets the preset discharging value in BATTERY CC/CR/CP mode.
Example
:SOURce:BATTery:LEVel 5.000
Command
Format
[:SOURce]:BATTery:LEVel?
Description
Query the discharging value in BATTERY CC/CR/CP mode.
Example
:SOURce:BATTery:LEVel?
Response
8.000
Command
Format
[:SOURce]:BATTery:VOLTage {< value > | MINimum |
MAXimum | DEFault}
Description
Sets the cut-off voltage value in BATTERY function.
Example
:SOURce:BATTery:VOLTage 9.000
Command
Format
[:SOURce]:BATTery:VOLTage?
Description
Query the cut-off voltage value in BATTERY function.
Example
:SOURce:BATTery:VOLTage?
Response
20.000
Command
Format
[:SOURce]:BATTery:CAPability < value >
Description
Sets the cut-off capacitance values in BATTERY function.
Example
:SOURce:BATTery: CAPability 100.00
Command
Format
[:SOURce]:BATTery:CAPability?
Description
Query the cut-off capacitance values in BATTERY function.
Example
:SOURce:BATTery: CAPability?
Response
199.000
Command
Format
[:SOURce]:BATTery:TIMer {< value > | MINimum | MAXimum |
DEFault}