Programming Guide

SIGLENT
SDL1000X Programming Guide 23
Command
Format
[:SOURce]:RESistance[:LEVel][:IMMediate]?
Description
Query the preset resistor value of CR mode in static operation.
Example
:SOURce:RESistance:LEVel:IMMediate?
Response
4.000
Command
Format
[:SOURce]:RESistance:IRANGe <value>
Description
Sets the current range of CR mode in static operation.
Example
:SOURce:RESistance:IRANGe 10
Command
Format
[:SOURce]:RESistance:IRANGe?
Description
Query the current range of CR mode in static operation.
Example
:SOURce:RESistance:IRANGe?
Response
30
Command
Format
[:SOURce]:RESistance:IRANGe <value>
Description
Sets the voltage range of CR mode in static operation.
Example
:SOURce:RESistance:IRANGe 60
Command
Format
[:SOURce]:RESistance:VRANGe?
Description
Query the voltage range of CR mode in static operation.
Example
:SOURce:RESistance:VRANGe?
Response
150
Command
Format
[:SOURce]:RESistance:RRANGe {LOW | MIDDLE | HIGH |
UPPER}
Description
Sets the resistor range of CR mode in static operation.
Example
:SOURce:RESistance:RRANGe MIDDLE
Command
Format
[:SOURce]:RESistance:RRANGe?
Description
Query the resistor range of CR mode in static operation.
Example
:SOURce:RESistance:RRANGe?
Response
UPPER
Command
[:SOURce]:RESistance:TRANsient:MODE {CONTinuous |