Programming Guide
SIGLENT
SDL1000X Programming Guide 20
Description
Sets the preset power value of CP mode in static operation.
Example
:SOURce:POWer:LEVel:IMMediate 3.000
Command
Format
[:SOURce]:POWer[:LEVel][:IMMediate]?
Description
Query the preset power value of CP mode in static operation.
Example
:SOURce:POWer:LEVel:IMMediate?
Response
4.000
Command
Format
[:SOURce]:POWer:IRANGe <value>
Description
Sets the current range of CP mode in static operation.
Example
:SOURce:POWer:IRANGe 10
Command
Format
[:SOURce]:POWer:IRANGe?
Description
Query the current range of CP mode in static operation.
Example
:SOURce:POWer:IRANGe?
Response
30
Command
Format
[:SOURce]:POWer:VRANGe <value>
Description
Sets the voltage range of CP mode in static operation.
Example
:SOURce:POWer:VRANGe 60
Command
Format
[:SOURce]:POWer:VRANGe?
Description
Query the voltage range of CP mode in static operation.
Example
:SOURce:POWer:VRANGe?
Response
30
Command
Format
[:SOURce]:POWer:TRANsient:MODE {CONTinuous | PULSe |
TOGGle}
Description
Sets the waveform mode of CP mode in transient operation.
Example
:SOURce:POWer:TRANsient:MODE TOGGle
Command
Format
[:SOURce]:POWer:TRANsient:MODE?
Description
Query the waveform mode of CP mode in static operation.
Example
:SOURce:POWer:TRANsient:MODE?