Programming Guide

SIGLENT
SDL1000X Programming Guide 15
Format
Description
Sets the voltage range of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:VRANGe 80
Command
Format
[:SOURce]:CURRent:TRANsient:VRANGe?
Description
Query the voltage range of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:VRANGe?
Response
150
Command
Format
[:SOURce]:CURRent:TRANsient:ALEVel {<value> | MINimum |
MAXimum | DEFault}
Description
Sets the A Level of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:ALEVel 4.653
Command
Format
[:SOURce]:CURRent:TRANsient:ALEVel?
Description
Query the A Level of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:ALEVel?
Response
6.000
Command
Format
[:SOURce]:CURRent:TRANsient:BLEVel {<value> | MINimum |
MAXimum | DEFault}
Description
Sets the B Level of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:BLEVel 5.000
Command
Format
[:SOURce]:CURRent:TRANsient:BLEVel?
Description
Query the B Level of CC mode in transient operation.
Example
:SOURce:CURRent:TRANsient:BLEVel?
Response
8.000
Command
Format
[:SOURce]:CURRent:TRANsient:AWIDth {<value> | MINimum |
MAXimum | DEFault}
Description
Sets the A Level pulse width time value of CC mode in transient
operation. Its unit is s
Example
:SOURce:CURRent:TRANsient:AWIDth 0.700
Command
Format
[:SOURce]:CURRent:TRANsient:AWIDth?