Programming Guide
SIGLENT
SDL1000X Programming Guide 13
Command
Format
[:SOURce]:CURRent[:LEVel][:IMMediate]?
Description
Query the preset current value of CC mode in static operation.
Example
:SOURce:CURRent:LEVel:IMMediate?
Response
2.674
Command
Format
[:SOURce]:CURRent:IRANGe <value>
Description
Sets the current range of CC mode in static operation.
Example
:SOURce:CURRent:IRANGe 10
Command
Format
[:SOURce]:CURRent:IRANGe?
Description
Query the current range of CC mode in static operation.
Example
:SOURce:CURRent:IRANGe?
Response
30
Command
Format
[:SOURce]:CURRent:VRANGe <value>
Description
Sets the voltage range of CC mode in static operation.
Example
:SOURce:CURRent:VRANGe 65
Command
Format
[:SOURce]:CURRent:VRANGe?
Description
Query the voltage range of CC mode in static operation.
Example
:SOURce:CURRent:VRANGe?
Response
36
Command
Format
[:SOURce]:CURRent:SLEW[:BOTH] {<value> | MINimum |
MAXimum | DEFault}
Description
Sets the slope of CC mode in static operation. The rise slope and
descending slope will be set synchronously.
Example
:SOURce:CURRent:SLEW:BOTH 0.652
Command
Format
[:SOURce]:CURRent:SLEW:POSitive {<value> | MINimum |
MAXimum | DEFault}
Description
Sets the rise slope of CC mode in static operation.
Example
:SOURce:CURRent:SLEW:POSitive 0.258
Command
[:SOURce]:CURRent:SLEW:POSitive?