User Manual
Table Of Contents
- General Safety Summary
- Introduction of SDG2000X
- Quick Start
- Front Panel Operations
- To Set Sine Waveform
- To Set Square Waveform
- To Set Ramp Waveform
- To Set Pulse Waveform
- To Set Noise Waveform
- To Set DC Waveform
- To Set Arbitrary Waveform
- To Set Harmonic Function
- To Set Modulation Function
- To Set Sweep Function
- To Set Burst Function
- To Store and Recall
- To Set Utility Function
- Examples
- Example 1: Generate a Sine Waveform
- Example 2: Generate a Square Waveform
- Example 3: Generate a Ramp Waveform
- Example 4: Generate a Pulse Waveform
- Example 5: Generate a Noise
- Example 6: Generate a DC Waveform
- Example7: Generate a Linear Sweep Waveform
- Example 8: Generate a Burst Waveform
- Example 9: Generate an AM Modulation Waveform
- Example 10: Generate a FM Modulation Waveform
- Example 11: Generate a PM Modulation Waveform
- Example 12: Generate a FSK Modulation Waveform
- Example 13: Generate an ASK Modulation Waveform
- Example 14: Generate a PSK Modulation Waveform
- Example 15: Generate a PWM Modulation Waveform
- Example 16: Generate a DSB-AM Modulation Waveform
- Troubleshooting
- Service and Support
- Appendix
SIGLENT
38 SDG2000X User Manual
waveform. The instrument outputs an arbitrary waveform which is made up of
certain points according to the current frequency
TrueArb
Choose Waveforms → Page 1/2 → Arb → Arb Mode and select the ―TrueArb‖
output mode. The parameters include sampling rate/frequency, amplitude/high
level, offset/ low level and phase.
Figure 2-19 Arb Parameters Display Interface (TrueArb)
Table 2-7 Menu Explanations of Arb Waveform (Page 1/2)
Function
menu
Settings
Explanations
SRate/
Frequency
Set the signal sampling rate or frequency;
The current parameter will be switched at a second press.
Amplitude/
HighLevel
Set the signal amplitude or high level;
The current parameter will be switched at a second press.
Offset/
LowLevel
Set the signal offset or low level;
The current parameter will be switched at a second press.
Phase
Set the phase of the signal.
In TrueArb output mode, users can set the sampling rate (the output points per
second) or frequency of the arbitrary waveform. The instrument outputs an