User Manual
Table Of Contents
- General Safety Summary
- Introduction of SDG2000X
- Quick Start
- Front Panel Operations
- To Set Sine Waveform
- To Set Square Waveform
- To Set Ramp Waveform
- To Set Pulse Waveform
- To Set Noise Waveform
- To Set DC Waveform
- To Set Arbitrary Waveform
- To Set Harmonic Function
- To Set Modulation Function
- To Set Sweep Function
- To Set Burst Function
- To Store and Recall
- To Set Utility Function
- Examples
- Example 1: Generate a Sine Waveform
- Example 2: Generate a Square Waveform
- Example 3: Generate a Ramp Waveform
- Example 4: Generate a Pulse Waveform
- Example 5: Generate a Noise
- Example 6: Generate a DC Waveform
- Example7: Generate a Linear Sweep Waveform
- Example 8: Generate a Burst Waveform
- Example 9: Generate an AM Modulation Waveform
- Example 10: Generate a FM Modulation Waveform
- Example 11: Generate a PM Modulation Waveform
- Example 12: Generate a FSK Modulation Waveform
- Example 13: Generate an ASK Modulation Waveform
- Example 14: Generate a PSK Modulation Waveform
- Example 15: Generate a PWM Modulation Waveform
- Example 16: Generate a DSB-AM Modulation Waveform
- Troubleshooting
- Service and Support
- Appendix
SIGLENT
28 SDG2000X User Manual
2.4 To Set Pulse Waveform
Press Waveforms key to select the waveform function, and press the Pulse
softkey. The pulse waveform parameters are set by using the pulse operation
menu.
The parameters for pulse waveforms include frequency/period, amplitude/high
level, offset/low level, width, rise/fall and delay. As shown in Figure 2-10, in the
soft key menu, select PulWidth. The pulse width parameter area is highlighted
in the parameter display window, and users can set the pulse width value
here.
Figure 2-10 Pulse Parameters Display Interface
Table 2-4 Menu Explanations of Pulse Waveform
Function
Menu
Settings
Explanation
Frequency/
Period
Set the signal frequency or period;
The current parameter will be switched at a second press.
Amplitude/
HighLevel
Set the signal amplitude or high level;
The current parameter will be switched at a second press.
Offset/
LowLevel
Set the signal offset or low level;
The current parameter will be switched at a second press.
PulWidth/
DutyCycle
Set the signal pulse width or duty cycle;
The current parameter will be switched at a second press.
Rise/
Fall
Setting the rise edge or fall edge for pulse waveform.
The current parameter will be switched at a second press.
Delay
Setting the delay for pulse waveform.