User Manual
Table Of Contents
- General Safety Summary
- Introduction of SDG2000X
- Quick Start
- Front Panel Operations
- To Set Sine Waveform
- To Set Square Waveform
- To Set Ramp Waveform
- To Set Pulse Waveform
- To Set Noise Waveform
- To Set DC Waveform
- To Set Arbitrary Waveform
- To Set Harmonic Function
- To Set Modulation Function
- To Set Sweep Function
- To Set Burst Function
- To Store and Recall
- To Set Utility Function
- Examples
- Example 1: Generate a Sine Waveform
- Example 2: Generate a Square Waveform
- Example 3: Generate a Ramp Waveform
- Example 4: Generate a Pulse Waveform
- Example 5: Generate a Noise
- Example 6: Generate a DC Waveform
- Example7: Generate a Linear Sweep Waveform
- Example 8: Generate a Burst Waveform
- Example 9: Generate an AM Modulation Waveform
- Example 10: Generate a FM Modulation Waveform
- Example 11: Generate a PM Modulation Waveform
- Example 12: Generate a FSK Modulation Waveform
- Example 13: Generate an ASK Modulation Waveform
- Example 14: Generate a PSK Modulation Waveform
- Example 15: Generate a PWM Modulation Waveform
- Example 16: Generate a DSB-AM Modulation Waveform
- Troubleshooting
- Service and Support
- Appendix
SIGLENT
26 SDG2000X User Manual
2.3 To Set Ramp Waveform
Press Waveforms key to select the waveform function, and press the Ramp
softkey. The ramp waveform parameters are set by using the ramp operation
menu.
The parameters for ramp waveforms include frequency/period, amplitude/high
level, offset/low level, phase and symmetry. As shown in Figure 2-8, in the soft
key menu, select Symmetry. The symmetry parameter area is highlighted in
the parameter display window, and users can set the symmetry value here.
Figure 2-8 Ramp Parameters Display Interface
Table 2-3 Menu Explanations of Ramp Waveform
Function
Menu
Settings
Explanation
Frequency/
Period
Set the signal frequency or period;
The current parameter will be switched at a second press.
Amplitude/
HighLevel
Set the signal amplitude or high level;
The current parameter will be switched at a second press.
Offset/
LowLevel
Set the signal offset or low level;
The current parameter will be switched at a second press.
Phase
Set the phase of the signal.
Symmetry
Set the symmetry for ramp waveform.