User Manual
Table Of Contents
- General Safety Summary
- Introduction of SDG2000X
- Quick Start
- Front Panel Operations
- To Set Sine Waveform
- To Set Square Waveform
- To Set Ramp Waveform
- To Set Pulse Waveform
- To Set Noise Waveform
- To Set DC Waveform
- To Set Arbitrary Waveform
- To Set Harmonic Function
- To Set Modulation Function
- To Set Sweep Function
- To Set Burst Function
- To Store and Recall
- To Set Utility Function
- Examples
- Example 1: Generate a Sine Waveform
- Example 2: Generate a Square Waveform
- Example 3: Generate a Ramp Waveform
- Example 4: Generate a Pulse Waveform
- Example 5: Generate a Noise
- Example 6: Generate a DC Waveform
- Example7: Generate a Linear Sweep Waveform
- Example 8: Generate a Burst Waveform
- Example 9: Generate an AM Modulation Waveform
- Example 10: Generate a FM Modulation Waveform
- Example 11: Generate a PM Modulation Waveform
- Example 12: Generate a FSK Modulation Waveform
- Example 13: Generate an ASK Modulation Waveform
- Example 14: Generate a PSK Modulation Waveform
- Example 15: Generate a PWM Modulation Waveform
- Example 16: Generate a DSB-AM Modulation Waveform
- Troubleshooting
- Service and Support
- Appendix
SIGLENT
SDG2000X User Manual 127
3.1 Example 1: Generate a Sine Waveform
Generate a sine waveform with 1MHz frequency, 5Vpp amplitude and 1Vdc
offset.
Steps:
Set the frequency.
1. Press Waveforms → Sine →Frequency/Period and choose Frequency
which will display in blue color.
2. Input ‗1‘ from the keyboard and choose the unit ‗MHz‘. The frequency is
set to 1MHz.
Set the Amplitude.
1. Press Amplitude/HighLevel to choose Amplitude which will display in blue
color.
2. Input ‗5‘ from the keyboard and choose the unit ‗Vpp‘. The amplitude is set
to 5Vpp.
Set the Offset.
1. Press Offset/LowLevel to choose Offset which will display in blue color.
2. Input ‗1‘ from the keyboard and choose the unit ‗Vdc‘. The offset is set to
1Vdc.
When the frequency, amplitude and offset are set, the waveform generated is
shown in Figure 3-1.