User's Manual

MOUNTING
The Sightmark Photon RT riescope requires 30mm scope rings (not included) for mounting. Mount the scope
per the scope ring manufacturer’s instructions. Do not perform a nal tightening of the rings prior to checking
eye relief and reticle alignment. Initially the riescope should still be able to move for and after and rotate when
installed in the rings.
To achieve maximum eye relief:
1. Turn the Photon RT on and focus the image. Set the riescope far forward in the rings and slowly move the
riescope closer to your eye. Stop moving the riescope once a full eld of view is visible.
2. Next rotate the scope to vertically align the crosshair. Use a reticle leveling tool if available.
3. Once alignment is complete, tighten the mounting ring’s screws evenly so the gap is even on both sides of the
scope. Do not over tighten.
Warning! If the riescope is not setup correctly with proper eye relief and is mounted too close to the shooter’s eye, it’s rearward motion due to rearm
recoil may cause injury to the shooter. To zero the scope, see section “One Shot Zeroing.
6
ON/OFF ACTIVATION
The Sightmark Photon RT controls are located on top of the unit for easy access.
To power the unit on:
1. Open the lens cover (2) if using at night. If using in daylight, keep cover closed.
2. Locate the on/o button (4) on top of the unit.
3. To turn the unit on, press the on/o button once. The display will turn on after several seconds.
4. To turn the display o, press the on/o button again for one second.
5. The message “Display o will appear on the screen. This mode saves battery life when the riescope is not be-
ing used in the eld, but operation can be started again quickly by briey pressing the on/o button again.