Manual
– 32 –
sig pro™
Service and Repairs
Assembly/Malfunction
Case ejection:
Spent case sticks in chamber or jams
in ejection port.
Misfire:
Hammer strikes, but no discharge.
Potential Cause
Recoil insufficient because
of fouling.
Underloaded ammunition.
Pistol defective.
Firing pin sticking in its guide.
Defective ammunition.
Pistol defective.
Potential Remedy
Strip, clean and lubricate pistol (see
Sect. 7.1–7.3)
Replace ammunition.
Repair by manufacturer.
Strip, clean and lubricate pistol (see
Sect. 7.1–7.3). Have pistol checked by
a rm o u re r.
Manually cycle slide to chamber new
round.
Repair by manufacturer.
9.2 Safekeeping and storage of the pistol
Always store your pistol unloaded and in cleaned condition.
Store your pistol separate from its ammunition and
under lock and key. The pistol and ammunition must not
be accessible to children and other inexperienced or
unauthorized persons.
9.3 Shipping the pistol
Familiarize yourself fully with local legislation governing the
shipping and transportation of firearms.
1. Check the pistol to ensure that it is unloaded and decocked.