User Manual
SOLID STATE FRYERS SPECIFICATIONS
5
SPECIFICATIONS
GAS SUPPLY AND BURNER INFORMATION
Supply pressure should be minimum of 4" W.C. for natural gas or 10" W.C. for propane. The fryer comes with ¾”
NPT male connector on a ½” pipe, allowing you to connect with either ¾” or ½” NPT female connector.
Model
Burners
Gas
Type
Manifold
Pressure
Number of
heat tube
Rate Each
BTUs / Hour
Total Rate
BTUs / Hour
Orifice Size
4 Burners Fryer -NG
4 Burners Fryer -LP
Main
Natural
4" W.C.
4
30,000
120,000
# 39
Propane
10" W.C.
4
30,000
120,000
# 52
5 Burners Fryer -NG
5 Burners Fryer -LP
Main
Natural
4" W.C.
5
30,000
150,000
# 39
Propane
10" W.C.
5
30,000
150,000
# 52
* Minimum supply pressure is 4" W.C. for natural gas and 10" W.C. for propane.
** Orifice sizes are for units installed at altitudes between 0 and 2,000 feet above sea level.