GSM Alert Threshold
This sets the number of times that wireless coverage must be lost before an alert
is raised. Values range from 1 to 5, and Off.
If sent directly to the device, the value is a decimal ASCII number (1 through 5, or
āNā for Off):
Battery Alert
This sets a combination of battery low-voltage and device shutdown alerts. Note
that battery voltage, not charge, is the defining parameter. Level 1 corresponds to
3.7V, and Level 2 corresponds to 3.8V. A voltage value greater than or equal to
3.9 means that the battery is fully charged.
If sent directly to the device, the value is a decimal ASCII number, as follows:
Configuration Editor
Direct to Device
No Battery Alert, No Shutdown Alert
Battery Alert at Level 1, No Shutdown Alert
Battery Alert at Level 2, No Shutdown Alert
Battery Alert at Level 1, Shutdown Alert active
Battery Alert at Level 2, Shutdown Alert active
No Battery Alert, Shutdown Alert active
0
1
2
3
4
5
Power Disconnect Alert
Indicates whether to send an alert when the power is disconnected. Check the
Enabled checkbox to enable the alert.
Note that the power being referred to is the external 5V USB power threshold, not
the internal power supply.
Over Speed Alert
Sets the speed at which the alert is triggered. Values range from 00 to FF
hexadecimal (0-255 decimal). A value of 00 indicates that the overspeed alert is
disabled.
Firmware Revision
Indicates the major and minor firmware revision numbers. Values range from 00
to FF hexadecimal (0-255 decimal). This is a read-only setting, and is shown in
the device management portal.