Specifications

Product Technical Specification & Customer Design Guidelines
16 Proprietary and Confidential - Contents subject to change 4114634
Temperature
· Operating temperature range (Class A): -30°C to +70°C
· Operating temperature range (Class B): -40°C to +85°C
Important: The internal module temperature must be kept below 100°C. For best perfor-
mance, the internal module temperature should be kept below 85°C. Proper mounting,
heat sinks, and active cooling may be required, depending on the integrated application.
Application interface features
USB interface (QMI) for Windows 7 and legacy Windows operating systems
MBIM for Windows 8
USB Link Power Management (LPM2) combined with selective suspend to
maximize power savings. Also supports fast wakeup.
AT command interface ([1] AT Command Set for User Equipment (UE)
(Release 6) (Doc# 3GPP TS 27.007), plus proprietary extended AT
commands in [2] AirPrime MiniCard MC73xx/MC8805 AT Command
Reference (Doc# 4114486))
Software Development Kits (SDK) for Windows 7 and Windows 8
Linux SDK, including a Linux API (Application Program Interface)
QDL loader compliant
Support for active antenna control via dedicated antenna control signals
(ANT_CTRL0:2)
Dynamic power reduction support via software and dedicated signal (DPR)
Note: Dial-up networking (DUN) is not supported.