Integration Guide
Routing Constraints and Recommendations
Rev 1 Jul 17 13 41111211
Note: The level of protection required depends on your application.
Mechanical Integration
Attention should be paid to:
• Antenna cable integration (bending, length, position, etc)
• Pads of the AirPrime WP7603 to be soldered to the ground plane
• Ensuring proper board layout
• Providing sufficient space around the module for heat dissipation
Table 4-1: ESD specifications
a,b
a. ESD specifications are preliminary, subject to change.
b. ESD protection is highly recommended at the point where the UIM contacts are exposed,
and for any other signals that would be subjected to ESD by the user.
Category Connection Specification
Operational RF ports
UIM connector
USB connector
UART connector
IEC-61000-4-2 - Level (Electrostatic Discharge
Immunity Test)
· ± 6kV Contact
· ± 8kV Air
Non-operational Host connector
interface
Unless otherwise specified:
• JESD22-A114 ± 1kV Human Body Model
• JESD22-A115 ± 100V Machine Model
• JESD22-C101C ± 500V Charged Device
Model