Specifications
Rev 1 Dec.10 Proprietary and Confidential - Specifications subject to change 81
Figure 6-1: Automatic (‘triggered’) power state transitions
Off mode
Handled by Power
State state machine.
Normal mode
Low power mode
Handled by Power
State state machine.
current_vcc > VOLT_LO_NORM
current_temp <= TEMP_HI_NORM
current_vcc < VOLT_LO_CRIT
current_temp > TEMP_HI_CRIT
current_vcc > VOLT_LO_NORM
current_temp < TEMP_HI_NORM
current_vcc < VOLT_LO_WARN
current_temp > TEMP_HI_WARN
current_vcc < VOLT_HI_NORM
current_temp > TEMP_NORM_LO
current_vcc > VOLT_HI_CRIT
current_temp < TEMP_LO_CRIT
(Manual transition)
Host asserts
W_Disable#
Normal mode
Low supply voltage warning
or
High temperature warning