Specifications
Product Technical Specification & Customer Design Guidelines
56 Proprietary and Confidential - Specifications subject to change 2400058
MIC single-ended connection example
Figure 4-6: Example—MIC single-ended connection with LC filter (TBD)
Single-ended connection considerations:
• Not recommended for improving TDMA noise rejection as it is usually difficult
to eliminate TDMA noise from a single-ended design.
• Internal input resistor value becomes 1150 due to the connection of
MIC1_N to the ground.
• LC filter (L1 and C2) is recommended (but not mandatory) to eliminate TDMA
noise. If the filter is not to be used, the capacitor C2 must be removed and the
coil replaced by 0 resistors as shown in Figure 4-7 on page 56.
Figure 4-7: Example - MIC single-ended connection without an LC filter (TBD)
Capacitor C1 is highly recommended to eliminate TDMA noise and it must be
connected close to the microphone.
AirPrime SL module
Audio
ADC
MIC
C1
C2
L1
S3
S4
MIC1_P
MIC1_N
1150 Ohm typ
100nF
100nF
1.2V typ
AirPrime SL module
Audio
ADC
MIC
C1
S3
S4
MIC1_P
MIC1_N
1150 Ohm typ
100nF
100nF
1.2V typ