Specifications

AirPrime UMTS / LTE MC/SL-Series Extended AT Command Reference
244 Proprietary and Confidential 2130616
Command reference
Table 11-2: PAD command details
Command Description
!PADCONF
Supporting chipsets:
MDM6200 (min f/w rev:
P1_0_0_0)
MDM6270 (min f/w rev:
S2.0)
MSM6290 (min f/w rev:
K2.0 Release 2)
QSC6270 (min f/w rev:
S2.0)
Note: This command is not
password-protected.
Configure profile options
Configure the PAD (Packet Assembler/Disassembler) session options and trigger
conditions for packetization on the transmit side.
Note: Multiple triggers can be active simultaneously. If any trigger condition is met,
packetization occurs.
This is a persistent setting (stored in NVRAM).
For PAD server profiles, this configuration applies to all PAD sessions connected to the
server.
Usage:
Execution: AT!PADCONF=<PADprofile>, <idle>, <interchar>, <pktlen>,
<fwdopt>, <fwdchar>
Response:
OK
or ERROR
Purpose: Configure trigger conditions for the specified <PADprofile>.
Query: AT!PADCONF?<PADprofile>
Response:
AT!PADCONF:<PADprofile>, <idle>, <interchar>, <pktlen>,
<fwdopt>,<fwdchar>
OK
Purpose: Return the current timer conditions for the specified <PADprofile>.
Parameters:
<PADprofile> (PAD profile ID number)
Valid range depends on multipad support:
Multipad not supported: 1–3
Multipad supported: 1–10
<idle> (Idle disconnect timeout trigger period)
Session disconnects if there is no data activity for this period of time.
Valid range: 0–65535 seconds (0Trigger disabled)
<interchar> (Inter-character timeout trigger period)
Packetization begins if the time interval between successive characters is
greater than this period of time.
Valid range: 0–65535 ms (0Trigger disabled)
<pktlen> (Packet length trigger)
Packetization begins when this many bytes have been collected.
Valid range: 0–1460 bytes (0Trigger disabled)
(Continued on next page)